<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-24 19-28-44
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
89.40 MHz 5/5, 70 dBuV ISKELMA
Pilot RDS Phase Difference
6.4 kHz 2.7 kHz -84 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
8 kHz 64 kHz 19080 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,5 dBr 5,78 dBr 6,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"ISKELMA " 62AD 9 (Varied) 1 0 1 1 --:--
RT
-
AF EON
89.4, 92.5, 95.0, 100.1 MHz -
FM Scope Max at: 64 kHz MIN: 8 kHz % above 76 kHz: 0,0000 Acquired: 2025/02/24 19.27.41 Total samples: 19080 Equivalent time: 0:15:54 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 2000 4000 6000
FM Scope MAX: 6,9 dBr MIN: 3,5 dBr AVE: 5,78 dBr % above 12,2 dBr: 0,0 Last value: 6,4 dBr (2025/02/24 19.27.41) 19.14 19.16 19.18 19.20 19.22 19.24 19.26 0 2 4 6 Pm [dBr]